Scan code to browse

Mobile version

Contact number

0577-5712 2266
Make a call

Product
CO-CTK/Y circular open close residual current transformer
CO-CTK/Y circular open close residual current transformer
Intro:Circular open close type residual current transformers are mainly used in cable circuit environments. They have simple structure, compact size, and flexible application. According to the specifications of the cables used in the main circuit, there are various perforation apertures corresponding. The diameter of the perforation hole in this series of products ranges from 25mm to 200mm, and the main circuit current includes 63A to 2000A. This series of products can meet the technical requirements of different accuracy levels such as 0.2, 0.5, and 1; At the same time, it can also meet the stringent requirements of the new national standard for balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, or even 3mA, greatly reducing false alarms caused by current magnetic field interference in the main circuit, providing sufficient assurance for the reliability of the equipment. Excellent production process. This series of products meets the requir
CO-CTK/YF rectangular open close residual current transformer
CO-CTK/YF rectangular open close residual current transformer
Intro:Rectangular open and close residual current transformers are mainly used in cable circuit environments. They have a simple structure, small size, and flexible application. According to the specifications of the cables used in the main circuit, there are various through-hole apertures corresponding. This series of products have through-hole apertures ranging from 110mm to 300mm, and the main circuit current contains 63A to 2000A. This series of products can meet the technical requirements of different accuracy levels such as 0.2, 0.5, and 1; At the same time, it can also meet the stringent requirements of the new national standard for balance characteristics. The unbalanced current output value can also be better than 30mA, 10mA, 5mA, or even 3mA, greatly reducing false alarms caused by current magnetic field interference in the main circuit, providing sufficient assurance for the reliability of the equipment. Excellent production process. This series of products meets the requirements
CO-BHO.66 Current Transformer
CO-BHO.66 Current Transformer
Intro:
COCB-125-External circuit breaker for electric energy meter
COCB-125-External circuit breaker for electric energy meter
Intro:Product Description: ● The control part adopts a single module design, with a width of only 27mm;

● Automatic opening and closing of arrears and payment; With fast tripping function (delinquent tripping can effectively prevent manual switching on and stealing electricity);

● The closing time of the operating mechanism to the circuit breaker is less than 2s, and the opening speed is less than 0.6s,

● The mechanical life is up to 20000 times, more than double that of domestic and foreign products;

● High breaking capacity Icu=10 KA,

● Internal shaft transmission is adopted to effectively ensure reliable synchronous closing of circuit breakers of 2P and above;

● Equipped with opening safety latch holes;

● The appearance and installation comply with the modular terminal combination electrical standards, with guide rail installation and convenient interchangeability;

● Low power consumption; All adopt environmentally friendly materials, which comply with RoHS;
COZR Intelligent Power Capacitor
COZR Intelligent Power Capacitor
Intro:
23456