Scan code to browse

Mobile version

Contact number

0577-5712 2266
Make a call

Transformer series
CO-CTKC puncture current transformer (with temperature)
CO-CTKC puncture current transformer (with temperature)
Intro:Puncture current transformer is installed online without power failure, with built-in current transformer, electric needle, temperature sensor, and a diversified design concept. It is easy to install. It is mainly used in power transformation and installation projects. All places where people operate are insulators, making installation safe, convenient, and simple. When installing the puncture type current transformer, the measured line passes through the middle hole, passes through the transformer, and outputs a current signal, which is converted into the required voltage signal through the sampling resistance, and is output as a lead wire.
CO-CTKC2 puncture current transformer (with wireless control module)
CO-CTKC2 puncture current transformer (with wireless control module)
Intro:Puncture current transformer (with wireless control module) is installed online without power failure, with built-in current transformer, electric needle, and temperature sensor. It has a diversified design concept and is easy to install. It is mainly used in power transformation and installation projects. All places where people operate are insulators, making installation safe, convenient, and simple. When installing the puncture type current transformer, the measured line passes through the middle hole, passes through the transformer, and outputs a current signal, which is converted into the required voltage signal through the sampling resistance, and is output as a lead wire.
CO-CC1 puncture clamp (with temperature)
CO-CC1 puncture clamp (with temperature)
Intro:The insulation puncture clamp mainly consists of a reinforced housing, stainless steel puncture needle, sealing pad, waterproof silicone grease, knob stainless steel bolt, and locking pressure plate knob. When the cable needs to be powered on, clamp the puncture plate into the cable branch line. After determining the main line branch position, rotate the fixed pressure plate. After the pressure plate is locked, rotate the puncture knob to contact the conductor, and the sealing pad presses around the punctured position of the cable, When the puncture needle pierces the cable and contacts the copper wire, a temperature sensor can be built in, and performance parameters can be customized.
CO-CC2 puncture clamp (with temperature)
CO-CC2 puncture clamp (with temperature)
Intro:The insulation puncture clamp mainly consists of a reinforced housing, stainless steel puncture needle, sealing pad, waterproof silicone grease, knob stainless steel bolt, and locking pressure plate knob. When the cable needs to be powered on, clamp the puncture plate into the cable branch line. After determining the main line branch position, rotate the fixed pressure plate. After the pressure plate is locked, rotate the puncture knob to contact the conductor, and the sealing pad presses around the punctured position of the cable, When the puncture needle pierces the cable and contacts the copper wire, a temperature sensor can be built in, and performance parameters can be customized.
CO-CTK/D open close current transformer
CO-CTK/D open close current transformer
Intro:The open and close type transformer is an improvement on the traditional transformer. It is made into a free opening and closing type, which can be quickly installed and disassembled without power failure and continuous wiring, and is easy to operate. This series of products has a wide measurement range, with a rated primary current range of 5~2000A, a rated secondary current range of 0~5A, and a current transformation ratio range of 500: 1~10000: 1. The orderly production process ensures its accuracy level, reliability, and other technical requirements. This product complies with the GB/T20840.1.2 standard.
CO-DPD open and close current transformer
CO-DPD open and close current transformer
Intro:Open and close current transformers are mainly used for cables and copper bars. Their structure is simple, design is reasonable, and application is flexible. According to the specifications of the cable copper bars used in the main circuit, there are various through-hole apertures corresponding. The primary current of the main circuit includes 50A to 4000A, and the rated secondary output current is 1A to 5A (0 to 1V). This series of products can meet the technical requirements of different accuracy levels such as 0.2, 0.5, and 1. GB/T20840.1.2。
CO-DP1 open close current transformer
CO-DP1 open close current transformer
Intro:Open and close current transformers are mainly used for cables and copper bars. Their structure is simple, design is reasonable, and application is flexible. According to the specifications of the cable copper bars used in the main circuit, there are various through-hole apertures corresponding. The primary current of the main circuit includes 50A to 6000A, and the rated secondary output current is 1A to 5A (0 to 1V). This series of products can meet the technical requirements of different accuracy levels such as 0.2, 0.5, and 1. GB/T20840.1.2。
CO-DP1 rectangular open close current sensor
CO-DP1 rectangular open close current sensor
Intro:Open and close current transformers are mainly used for cables and copper bars. Their structure is simple, design is reasonable, and application is flexible. According to the specifications of the cable copper bars used in the main circuit, there are various through-hole apertures corresponding. The primary current of the main circuit includes 50A to 6000A, and the rated secondary output current is 1A to 5A (0 to 1V). This series of products can meet the technical requirements of different accuracy levels such as 0.2, 0.5, and 1. GB/T20840.1.2。
CO-DP2 open close current transformer
CO-DP2 open close current transformer
Intro:Open and close current transformers are mainly used for cables and copper bars. Their structure is simple, design is reasonable, and application is flexible. According to the specifications of the cable copper bars used in the main circuit, there are various through-hole apertures corresponding. The primary current of the main circuit includes 50A to 6000A, and the rated secondary output current is 1A to 5A (0 to 1V). This series of products can meet the technical requirements of different accuracy levels such as 0.2, 0.5, and 1.
CO-CTKD/G fixed switching current transformer
CO-CTKD/G fixed switching current transformer
Intro:Fixed open and close current transformers are mainly used for cables and copper bars. They have a simple structure, reasonable design, and flexible application. According to the specifications of the cable copper bars used in the main circuit, there are various through-hole apertures corresponding. The primary current of the main circuit includes 50A to 6000A, and the rated secondary output current is 1A to 5A (0 to 1V). This series of products can meet the technical requirements of different accuracy levels such as 0.2, 0.5, and 1.
CO-K38 Open ended current transformer
CO-K38 Open ended current transformer
Intro:Fixed open and close current transformers are mainly used for cables and copper bars. They have a simple structure, reasonable design, and flexible application. According to the specifications of the cable copper bars used in the main circuit, there are various through-hole apertures corresponding. The primary current of the main circuit includes 50A to 6000A, and the rated secondary output current is 1A to 5A (0 to 1V). This series of products can meet the technical requirements of different accuracy levels such as 0.2, 0.5, and 1.
CO-CTHW open and close outdoor waterproof transformer
CO-CTHW open and close outdoor waterproof transformer
Intro:Open and close outdoor waterproof transformer. The characteristic of this series of transformer is its waterproof function, which can be used outdoors. Its cut port is surrounded by rubber pads to prevent rainwater from entering. Of course, most of the so-called waterproof transformers on the market use rubber pads, but using this method alone for waterproof also has limitations, because it is impossible to ensure the waterproof of the transformer body, and our company adopts the transformer secondary molding technology, The transformer is directly made into a solid body in the mold, with plastic covering the entire body without gaps. At the same time, the secondary side bow line uses waterproof terminals and sheathed wires to ensure that no trace of rain can enter the transformer body. After testing by authoritative institutions, our company's transformer waterproof grade reaches IP57. This product meets the requirements of part of the standard GB20840.1.2.